Route your first pipe
You will connect a sink's drain to a sanitary pipe that is already in your project, with a 2% slope and a P-trap. It takes about 15 minutes.
You need: a sink with a free drain connector, and a horizontal sanitary pipe near it (the main). Prepare your project

1. Make the routing preference#
The routing preference holds the rules for this pipe. You make it once.
Open Routing Preferences
PipeIt tab › Control Panel › the second icon, Routing Preferences.
Click Branch Into a Pipe
Branch means the new pipe joins a pipe that is already there. Already have routing preferences? Click + Branch at the top instead.

Name it
Type Sink to Pipe in Preference Name.
Route Settings: slope 2% Down, 45° elbows
Slope › 2.00 %, and Down. Elbow Style › 45° horizontal, 90° vertical.

No 45° elbows in your pipe type? Choose All 90°. The pipe then joins the main with a Tee, not a Wye.
Pipe Assignment: Pick from Model, then click the main
The pipe type and system become the main's. If Diameter changes, set it back to Auto, so the pipe takes the sink's size.
Pick from Model, click the main, Diameter back to Auto. P-Trap Settings: tick Add P-Trap
Choose your trap in P-Trap Type. Leave Branch Fitting on Wye and Side.

Click Save Preference

2. Pick the sink and the main#
Click ▷ on the card
▷ is left of the name. It turns into ✓, and the Route window opens.

Click Pick start, then click the sink
Click Pick end, then click the main
Click the main near the sink. The pipe joins near your click.
Click Run
Pick the sink, pick the main, then Run.
A row turned red? That pick can't be used. Read the red box, then click Re-pick. More help
3. Pick the spaces, then Generate#
Path Selection opens. Plumbing Copilot has found the walls, floors and ceiling spaces around your picks. You tell it which ones the pipe should use.
Look at Next step
It lists the spaces the pipe can go into next. A * marks one that reaches the end.

Click the spaces the pipe should use
For example the Wall behind the sink, then the Floor, then the CeilingVoid marked *. A chip with ×2 or ×3 opens a list: pick one. The strip at the top shows your path.
Pick the wall, the floor and the ceiling void (sped up). Check, then click Generate
The strip ends with your last pick, the badge says Ready, and the sentence at the bottom says "The path reaches the end. Press Generate."

◀ in the strip undoes the last pick, ↺ starts again. With no picks at all, Generate routes freely, through any space it finds.
Red badge instead? 1 conflict · Blocked
4. Wait for the search#
The Route Search window finds the routes. It often takes under a minute.
No route found? Fix it
5. Choose a route, then Confirm#
Click ▶ and ◀ to look at the routes
Each one is a different way the pipe can run. Sort By puts the ones with the fewest fittings, or the shortest, first.
Look at the routes with ▶, then Confirm. Choose the route that fits your design, then click Confirm
The top of the window shows its length, its fittings and its clashes.

6. Check it in Revit#
The pipe, the Wye on the main and the P-trap at the sink are in your model. Click a pipe: it is a normal Revit pipe, with your pipe type and system.

Want to try again? Press Ctrl+Z until the route is gone, then click ✓ on the card again.
Next#
- More rules and settings: Routing preferences
- Other pipes: Examples