Beginner

Path Selection and Route Selection

After you click Run in the Route window, two windows follow:

  1. Path Selection: you pick the spaces the pipe uses, then click Generate.
  2. Route Selection: you compare the routes Plumbing Copilot found and click Confirm on one.

Path Selection#

Plumbing Copilot finds the walls, floors and ceiling spaces around your start and end. You pick the ones the pipe should go through.

  1. Look at Next step

    It lists the spaces the pipe can go into next. A * marks one that reaches the end.

    Path Selection before any pick: under Next step, the chips CeilingVoid (marked with a star), Floor and Wall are boxed.
  2. Click the spaces the pipe should use

    One after the other, until you pick one marked *. A chip with ×2 or ×3 opens a list: pick one from it.

    Picking the wall, the floor and the ceiling void (sped up).

    Until your picks reach the end, the badge says Incomplete and Generate is gray.

    Path Selection after one pick: the badge Incomplete, the Floor list open with three floors to choose from, and the sentence Keep picking until an element marked * reaches the end, all boxed.
  3. When the badge says Ready, click Generate

    The sentence at the bottom says "The path reaches the end. Press Generate."

    Path Selection after three picks: the path strip, the badge Ready, the sentence The path reaches the end. Press Generate, and Generate, all boxed.

◀ in the strip at the top undoes the last pick, ↺ starts again. With no picks at all, Generate routes freely, through any space it finds.

BadgeMeansDo this
Ready (green)It can go ahead.Click Generate.
Incomplete or Dead end (amber)Your picks don't reach the end yet, or nothing continues from the last one.Keep picking, or click ◀ to undo the last pick.
1 conflict (red)The slope or the elbows don't work with the start or end.Fix it
Blocked (red)Something is in the way.Fix it

Cancel closes the window. Nothing is added to your model.

Keep away from ducts and beams#

New pipes go around the elements whose categories are ticked on the Obstacle Avoidance tab, in your model and in linked models.

  1. Open the Obstacle Avoidance tab

    Control Panel › the shield icon, the third.

  2. Tick the categories new pipes must go around

    For example Ducts and Structural Framing (beams). Select All ticks every category. It is saved at once.

    The Obstacle Avoidance tab with every category ticked; Ducts, Structural Framing, and the Select All and Deselect All buttons are boxed.

The gap kept around them is the routing preference's Clearance, under Advanced options.

After Generate, the Route Search window looks for routes. It often takes under a minute. Stop Search stops it.

The Route Search window: Searching for routes, a progress bar, the time and the routes found so far, and Stop Search.

No route found? The window says why and may offer a fix. No route found

Route Selection#

  1. Click ▶ and ◀ to look at each route

    The top of the window shows the route's length, its fittings and its clashes.

    Look at each route with ▶, then Confirm.
  2. Choose the route that fits your design

    Sort By puts the routes with the fewest fittings, or the shortest, first.

  3. Click Confirm

    The route is placed in your model. Cancel places nothing.

    Route Selection showing Route 4 of 20: the clash badge No Clashes, the route picker with its arrows, and Confirm are boxed.

The placed route#

It is normal Revit pipe and fittings: move, edit or delete it like any pipe. To remove it, press Ctrl+Z until it is gone.

"The route was not built"? Fix it